Specifications
Electric
Supply voltage: 380-415 V/3N ph/50 Hz
Default Installed Power: 59.8 kW
Pre-wash tank heating elements: 14 kW
Wash tank heating elements: 20 kW
Triple tank heating elements: 7 kW
Boiler heating elements: 14 kW
Pre-wash pump size: 1,5 kW
Wash pump size: 1,5 kW
Rinse pump size (final, duo, triple): 0.55 / 0,32 / 0,32 kW
Water
Inlet water line size: G 3/4"
Inlet cold water line size: G 3/4"
Drain line size: 50mm
Inlet water supply pressure: 1.5-6 bar
Inlet water supply temperature (wash and rinse): 10 - 65°C
The higher the temperature, the faster the warm-up.
Recommended temperature: 50°C.
Inlet water supply temperature (rinse and pre-wash): 10 - 30 °C
Inlet water supply hardness: 0 °fH / 0°dH
When below 7°fH/4°dH special detergent and rinse aid are needed.
Peak rate of drain flow: 18 l/s
Pre-wash tank size: 70 l
Wash tank size: 70 l
Duo rinse tank size: 20 l
Triple rinse tank size: 20 l
Rinse water consumption at max. speed (l/h): 140l/h
Sustainability
Rinse water consumption at max. speed (l/rack)*: 0.9
Noise level: 58 dBA
Key Information
Productivity per hour (2° speed): 120 racks / 1440 dishes
Productivity per hour (A0 60 certified speed): 70racks/840dishes
Productivity per hour (DIN 10510 certified speed): 150 racks / 1800 dishes
Pre-wash temperature: 40-70°C
Wash temperature: 75 - 85 °C
Triple rinse temperature: 80 - 85 °C
Duo rinse temperature: 75 - 80 °C
Final rinse temperature: 90 °C
External dimensions, Width: 3270 mm
External dimensions, Depth: 895 mm
For transportation purpose only, the depth can be reduced to 795mm by removing the control box and the door handles.
External dimensions, Height: 1785 mm
Height with door open: 2095 mm
Charging hole size (width): 530 mm
Charging hole size (height): 490 mm
Net weight: 569 kg
Shipping weight: 647 kg
Shipping height: 1980 mm
Shipping width: 3450 mm
Shipping depth: 1060 mm
Shipping volume: 7.24 m³
Reference norm used to measure the noise: IEC60335-2-58 annex AA.
Table to table distance: 3270 mm
Air Emission
Air flow (top, exit): 86 / 145 m³/h
Air temperature: 27 - 45 °C
Air humidity (top, exit): 100 / 100 % r.h.
The data is measured at exhaust points at 25°C and 60% r.h. ambient conditions, 18°C inlet water temperature and refer only to the machine.
Latent heat: 6500 W
Sensible heat: 5300 W
This model requires a ventilation hood. Please refer to the attached "Recommended Exhaust Hood Design".