Single Rinse Rack Type dishwashers - 100 racks per hour

Liên hệ

 

Warewashing Single rinse Rack Type dishwasher, 100 racks/hour, electric
Single Rinse Rack Type Dishwasher, 100 racks/hour, electric, touch screen, insulated doors, customized direction on-site, 50Hz

 



 

Specifications
Electric
Supply voltage: 380-415 V/3N ph/50 Hz
 
Default Installed Power: 25.2 kW
 
Boiler heating elements: 12 kW
 
Wash pump size: 1.18 kW
 
Wash tank heating elements: 12 kW
 
Water
Flow rate of wash pump: 400 l/min
 
Inlet hot water line size: G 3/4"
 
Inlet cold water line size:
 
Drain line size: 50mm
 
Inlet water supply pressure: 1.5-7 bar
 
Inlet water supply temperature (wash and rinse): 50 - 65°C
 
The higher the temperature, the faster the warm up. When there is ESD option installed, the machine should be connected to cold water up to 30°C.
 
Inlet water supply hardness: 0 °fH / 0°dH
 
When below 7°fH/4°dH special detergent and rinse aid are needed.
 
Wash tank size: 70 l
 
Key Information
Wash Temperature: 55 - 65 °C
 
Productivity per hour (max speed): 100racks/1800dishes
 
Final rinse temperature: 85 °C
 
External dimensions, Width: 44 1/16" (1120 mm)
 
External dimensions, Depth: 920 mm
 
For transportation purpose only, the depth can be reduced to either 890mm by removing the main switch button or 792mm by removing the control box and the door handle.
 
Height with door open: 2095 mm
 
Charging hole size (width): 530 mm
 
Charging hole size (height): 490 mm
 
Shipping height: 1970 mm
 
Shipping width: 1060 mm
 
Shipping depth: 1260 mm
 
Shipping volume: 2.63 m³
 
Reference norm used to measure the noise: IEC60335-2-58 annex AA.
 
Table to table distance: 1120 mm
 
Sustainability
Rinse water consumption at max speed (l/rack): 1.5 lt/rack
 
Rinse water consumption at max. speed (l/h): 150 l/h
 
Noise level: <62 dBA
 
Air Emission
Air flow (top, exit): 107 / 107 m³/h
 
Air temperature: 45 - 45 °C
 
Air humidity (top, exit): 100 / 100 % r.h.
 
The data is measured at exhaust points at 25°C and 60% r.h. ambient conditions, 18°C inlet water temperature and refer only to the machine.
 
Latent heat: 8800 W
 
Sensible heat: 4500 W
 
This model requires a ventilation hood. Please refer to the attached "Recommended Exhaust Hood Design"